23 research outputs found

    Detection of joint inflammation in rheumatoid arthritis using multispectral diffuse optical imaging

    Get PDF
    Rheumatoid arthritis is a chronic autoimmune disease, characterised by joint inflammation, which if untreated causes disability. A clinical need exists for novel, low-cost and noninvasive imaging tools capable of detecting inflammation in the joints for the diagnosis and monitoring of patients with rheumatoid arthritis. Diffuse optical imaging provides information about the underlying functional properties of biological tissue and previous studies have reported an optical contrast between inflamed and non-inflamed joints, with former displaying localised increases in absorption and scattering attributed to underlying pathophysiological changes. In this work, a novel, multispectral diffuse optical imaging system for imaging human hand joints was presented, which combined surface imaging and optical transmission imaging in a single work-flow to reconstruct maps of clinically relevant parameters such as oxygen saturation, total haemoglobin, water and scattering amplitude in three dimensions. The system was designed to provide accurate, robust and rapid data acquisition, particularly through the novel application to joint imaging of a galvanometer-based unit for fast source repositioning allowing full datasets to be acquired in 2mins per joint, such as to be sufficient for implementation in a clinical setting. This clinical prototype system was then comprehensively studied through experiments involving biological tissue mimicking optical phantoms, to assess performance against a ground truth set of known parameters. Preliminary studies involving healthy volunteers gave useful insight into the systems in vivo performance and provided a good understanding of baseline values in healthy subjects, with significantly greater variability observed between subjects than when comparing joints within the same subject. A pilot clinical study was then carried out, involving 144 joints from 21 rheumatology patients with ultrasound imaging and clinical examination as reference comparisons, to assess the systems diagnostic accuracy capabilities. A degree of sensitivity was observed from three dimensional maps of total haemoglobin and scattering amplitude to pathophysiological changes in the joint during longitudinal monitoring of either recovery from acute injury in a single healthy subject or the response to therapy in rheumatoid arthritis patients. From single time-point examination data, classification accuracies when considering the entire cohort were limited, with areas under the receiver operator curve of up to 0.657 achieved, with similar conclusions reached to those in comparable single-wavelength, continuous-wave studies previously reported despite the multiple wavelength acquisition. A normalised Fourier transform methodology was then presented, engineered to extract features related to the spatial signature of the transmitted light through the joint that were less sensitive to inter-subject variability in total flux for the assessment of optical transmission images. For the first time within the academic community, to the authors knowledge, the impact on diffuse optical imaging signals of the spatially asymmetrical prevalence of inflammation in hand joints of rheumatoid arthritis patients was addressed. In distinction from previous work, optical images were acquired from the dorsal side with illumination on the palmar side and results when using the proposed normalised fast Fourier transform methodology demonstrated accurate detection of inflamed joints from single time-point examinations, with of area under the receiver operator curve values up to 0.888 together with sensitivities and specificities of up to 77.9% and 90.9% respectively achieved for this specific dataset. This work-flow may enable future development of clinically viable, low-cost devices for assessing inflammation in arthritis patients, without the need for cuff occlusion or comparison to baseline. It will be important to assess the generalisation of these accuracies in future work, using a larger patient cohort and testing different machine learning classification schemes

    A molecular assay for sensitive detection of pathogen-specific T-cells.

    Get PDF
    Here we describe the development and validation of a highly sensitive assay of antigen-specific IFN-γ production using real time quantitative PCR (qPCR) for two reporters--monokine-induced by IFN-γ (MIG) and the IFN-γ inducible protein-10 (IP10). We developed and validated the assay and applied it to the detection of CMV, HIV and Mycobacterium tuberculosis (MTB) specific responses, in a cohort of HIV co-infected patients. We compared the sensitivity of this assay to that of the ex vivo RD1 (ESAT-6 and CFP-10)-specific IFN-γ Elispot assay. We observed a clear quantitative correlation between the two assays (P<0.001). Our assay proved to be a sensitive assay for the detection of MTB-specific T cells, could be performed on whole blood samples of fingerprick (50 uL) volumes, and was not affected by HIV-mediated immunosuppression. This assay platform is potentially of utility in diagnosis of infection in this and other clinical settings

    Multispectral diffuse optical tomography of finger joints

    No full text
    Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by synovial inflammation. The current treatment paradigm for earlier, more aggressive therapy places importance on development of functional imaging modalities, capable of quantifying joint changes at the earliest stages. Diffuse optical tomography (DOT) has shown great promise in this regard, due to its cheap, non-invasive, non-ionizing and high contrast nature. Underlying pathological activity in afflicted joints leads to altered optical properties of the synovial region, with absorption and scattering increasing. Previous studies have used these optical changes as features for classifying diseased joints from healthy. Non-tomographic, single wavelength, continuous wave (CW) measurements of trans-illuminated joints have previously reported achieving this with specificity and sensitivity in the range 80 - 90% [1]. A single wavelength, frequency domain DOT system, combined with machine learning techniques, has been shown to achieve sensitivity and specificity in the range of 93.8 - 100% [2]. A CW system is presented here which collects data at 5 wavelengths, enabling reconstruction of pathophysiological parameters such as oxygenation and total hemoglobin, with the aim of identifying localized hypoxia and angiogenesis associated with inflammation in RA joints. These initial studies focus on establishing levels of variation in recovered parameters from images of healthy controls.</p

    Development of a cost effective optical imaging system for monitoring of Rheumatoid Arthritis

    No full text
    Rheumatoid Arthritis (RA) affects a significant portion of the population, but early treatment can improve patient outcomes. A low-cost, streamlined system has been developed for monitoring the progression of RA and inform treatment during this critical early window.</p

    Development of a cost effective optical imaging system for monitoring of Rheumatoid Arthritis

    No full text
    Rheumatoid Arthritis (RA) affects a significant portion of the population, but early treatment can improve patient outcomes. A low-cost, streamlined system has been developed for monitoring the progression of RA and inform treatment during this critical early window.</p

    Utilization of spatial derivative measurements in circular diffuse optical tomographic imaging to improve image resolution and contrast

    No full text
    The resolution of images recovered using diffuse optical tomography without spatial prior information is inherently limited due to the diffusive nature of light transport in scattering dominated biological tissue. Several studies have previously reported an improvement in depth sensitivity in near infra-red spectroscopy by considering the subtraction of two neighbouring measurements. A nearest neighbour, spatial derivative based algorithm is presented, in which the difference between neighbouring source-sharing source-detector pairs is considered for tomographic reconstruction. Using a circular, inward-facing optode geometry, it is shown that deeper abnormalities in oxyhaemoglobin, deoxyhaemoglobin and water can be recovered with better localisation and contrast as compared to reconstructing using absolute values of multi-wavelength data. Relative improvements of up to 25% in quantitative accuracy of recovered physiological values are demonstrated at better resolution for cancerous tissue in a heterogeneous breast model, when using this proposed spatial derivative based parameter reconstruction
    corecore